Applications
Features
Technical data
|
|
Environmental class |
EN1434/MID E2+M2 (optional E1+M1) |
Ambient operating temperature(℃) |
-25~55 |
Battery supply |
3.6V lithium battery up to 12 years lifetime① |
External power |
(5~24)VDC |
Mount position |
Any angle |
Protection class |
IP68 |
Interface |
open collector (pulse output and communication②) |
Pulse duration |
Defult 25 ms (2.5ms for test mode) |
|
Can be set by customer requirement by software |
Cable length |
Default 3m (3m~20m optional) |
Operating pressure |
16 bar with flanged connection (optional 25 bar) |
Temperature input
|
|
Absolute Temperature measuring range Θ ℃ |
1 ~150 |
Dimensions
(DN50~DN100)
(DN125~DN300)
Max. Operating pressure: PN16 |
|||||||||||
Nominal diameter |
DN |
mm |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
Length |
L |
mm |
200/270 |
200/300 |
225/300 |
250/360 |
250/350 |
300/350/500 |
350/500 |
400/600 |
450/500 |
Diameter |
D |
mm |
165 |
185 |
200 |
220 |
250 |
285 |
340 |
405 |
460 |
Heigth |
H |
mm |
221 |
232 |
253 |
273 |
360 |
390 |
450 |
510 |
565 |
Hole circle |
K |
mm |
125 |
145 |
160 |
180 |
210 |
240 |
295 |
355 |
410 |
Diameter |
n×φL |
|
4×φ18 |
4×φ18 |
8×φ18 |
8×φ18 |
8×φ18 |
8×φ22 |
12×φ22 |
12×φ26 |
12×φ26 |
|
|
|
|
|
|
|
|
|
|
|
|
Max. Operating pressure: PN25 |
|||||||||||
Nominal diameter |
DN |
mm |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
Length |
L |
mm |
200/270 |
200/300 |
225/300 |
250/360 |
250/350 |
300/350/500 |
350/500 |
400/600 |
450/500 |
Diameter |
D |
mm |
165 |
185 |
200 |
235 |
270 |
300 |
360 |
425 |
485 |
Heigth |
H |
mm |
221 |
232 |
253 |
282 |
370 |
400 |
450 |
520 |
575 |
Hole circle |
K |
mm |
125 |
145 |
160 |
190 |
220 |
250 |
310 |
370 |
430 |
Diameter |
n×φL |
|
4×φ18 |
4×φ18 |
8×φ18 |
8×φ22 |
8×φ26 |
8×φ26 |
12×φ26 |
12×φ30 |
12×φ30 |
|
|
|
|
|
|
|
|
|
|
|
|
Nominal diameter |
|
mm |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
Reference Threshold flow rate |
|
m³/h |
0.01 |
0.02 |
0.03 |
0.05 |
0.08 |
0.1 |
0.2 |
0.3 |
0.4 |
Minimum flow |
qi |
m³/h |
0.06 |
0.1 |
0.16 |
0.24 |
0.4 |
0.6 |
1 |
1.6 |
2.4 |
Nominal flow rate |
qp |
m³/h |
15 |
25 |
40 |
60 |
100 |
150 |
250 |
400 |
600 |
Maximum flow |
qs |
m³/h |
30 |
50 |
80 |
120 |
200 |
300 |
500 |
800 |
1200 |
Default working pulse value① |
|
L/pulse |
0.5 |
1 |
2 |
2.5 |
5 |
5 |
10 |
15 |
20 |
Pulse value in test mode |
|
L/pulse |
0.05 |
0.1 |
0.25 |
0.25 |
0.5 |
0.5 |
1 |
2 |
2.5 |
① Default working pulse value can be set by customer requirements by software.
Flow sensor installation
Note:
The straight pipe requirements marked in the figure are not mandatory, upstream 3 and downstream 0 is acceptable.