LCN Flow Sensor

 

 

 

Important Notice                                                                                         

  • Please read this manual carefully before undertaking the installation!
  • RC Series ultrasonic flow sensors must be installed by qualified personnel in accordance with the instructions given in this manual.
  • RC takes no responsibility for difficulties arising from failure to observe these instructions.
  • These instructions should be handed over to the user upon completion of the installation. They should be kept for future reference.
  •    Seals on the heat-meter must not be damaged. Breaking or damaging meter seals is seen as violation of the equipment.

Applications

  • Ultrasonic flow sensor for use with energy calculators for heating and cooling applications.

Features

  • Static sensor based on the ultrasonic transit time Principle.
  • Ultrasonic flow sensor for use with energy calculators for heating and cooling applications.
  • Low power consumption, long battery life.
  • Low start-up value and high measurement dynamics.
  • Measurement accuracy meets EN1434 and MID class 2 and 3 .
  • Flow-optimised design.
  • Approved range of measurement 1:250 (only for DN50~DN100 in horizontal, others 1:100) in class 2.
  • Pulse value can be set free.

Technical data

 

 

Environmental class

EN1434/MID E2+M2 (optional E1+M1)

Ambient operating temperature(℃)

-2555

Battery supply

3.6V lithium battery up to 12 years lifetime

External power

(5~24)VDC

Mount position

Any angle

Protection class

IP68

Interface

open collector (pulse output and communication)

Pulse duration

Defult 25 ms (2.5ms for test mode)

 

Can be set by customer requirement by software

Cable length

Default 3m (3m20m optional)

Operating pressure

16 bar with flanged connection (optional 25 bar)

 

  • In normal ambient temperature conditions, also depends on the data transmission frequency and correct flow sensor battery installation (positive electrode on the top).
  • VMCP interface

Temperature input

 

 

Absolute Temperature measuring range Θ

1 150

Dimensions

    (DN50~DN100)                 

            (DN125~DN300

 

Max. Operating pressure: PN16

Nominal diameter

DN

mm

50

65

80

100

125

150

200

250

300

Length

L

mm

200/270

200/300

225/300

250/360

250/350 

300/350/500

350/500

400/600

450/500

Diameter

D

mm

165

185

200

220

250

285

340

405

460

Heigth

H

mm

221

232

253

273

360

390

450

510

565

Hole circle

K

mm

125

145

160

180

210

240

295

355

410

Diameter

φL

 

φ18

φ18

φ18

φ18

φ18

φ22

12×φ22

12×φ26

12×φ26

 

 

 

 

 

 

 

 

 

 

 

 

   Max. Operating pressure: PN25

Nominal diameter

DN

mm

50

65

80

100

125

150

200

250

300

Length

L

mm

200/270

200/300

225/300

250/360

250/350 

300/350/500

350/500

400/600

450/500

Diameter

D

mm

165

185

200

235

270

300

360

425

485

Heigth

H

mm

221

232

253

282

370

400

450

520

575

Hole circle

K

mm

125

145

160

190

220

250

310

370

430

Diameter

φL

 

φ18

φ18

φ18

φ22

φ26

φ26

12×φ26

12×φ30

12×φ30

 

 

 

 

 

 

 

 

 

 

 

 

Nominal diameter

 

mm

50

65

80

100

125

150

200

250

300

Reference Threshold flow rate

 

m³/h

0.01

0.02

0.03

0.05

0.08

0.1

0.2

0.3

0.4

Minimum flow

qi

m³/h

0.06

0.1

0.16

0.24

0.4

0.6

1

1.6

2.4

Nominal flow rate

qp

m³/h

15

25

40

60

100

150

250

400

600

Maximum flow

qs

m³/h

30

50

80

120

200

300

500

800

1200

Default working pulse value

 

L/pulse

  0.5

  1

  2

   2.5

  5

  5

  10

  15

  20

Pulse value

 in test mode

 

L/pulse

0.05

0.1

0.25

0.25

0.5

0.5

1

2

2.5

Default working pulse value can be set by customer requirements by software.

Flow sensor installation

 

 

Note

The straight pipe requirements marked in the figure are not mandatory, upstream 3 and downstream 0 is acceptable.

 

 